This is fairly easy. Put a shield icon on the button that saves changes to the configuration file, instead of the menu item. This follows the Windows behavior of not requesting UAC permissions until the last moment. The button actually will launch your executable again as administrator with a special command line (that you decide) to perform the configuration file saving. Use a named pipe (be sure to give it the correct permissions) to pass the configuration data to your second instance if your don't want to use the command line for data passing.
For launching your executable:
ProcessStartInfo info = new ProcessStartInfo();
info.FileName = "YOUR EXE";
info.UseShellExecute = true;
info.Verb = "runas"; // Provides Run as Administrator
info.Arguments = "YOUR SPECIAL COMMAND LINE";
if (Process.Start(info) != null)
{
// The user accepted the UAC prompt.
}
This works also when UAC doesn't exist (Windows XP), because it will simply run as administrator if possible, or prompt for credentials. You can check whether the OS requires UAC by simply doing Environment.OSVersion.Version.Major == 6
. 6 is both Windows Vista and 7. You can make sure you're using Windows by looking at Environment.OSVersion.Platform
.
For detecting whether you're application is already admin, you can do this:
public static bool IsAdministrator()
{
WindowsIdentity identity = WindowsIdentity.GetCurrent();
if (identity != null)
{
WindowsPrincipal principal = new WindowsPrincipal(identity);
return principal.IsInRole(WindowsBuiltInRole.Administrator);
}
return false;
}